Household Air and Water Quality Monitor Tradesalon.Net
BT401 BT402 BT403 BT404

BT405 BT406 BT409 BT410A
BT407 BT408 BT410B BT410C

Model BT401
INTRODUCTION
This Air Ion Tester is designed for testing negative & positive air ion concentration of air ion generator. With it you can estimate whether the air ion generator or air purifier operate in good state.

The reading of this tester is correlative to the air ion concentration, but not exact the number of it. To make the reading display the concentration, you may calibrate the reading of this tester with a standard Air Ion Detector, as DLY-3 Air Ion Detector.

It can be hung like a necklace used as decorations or packed in bags.
This tester is suit for all kinds of positive or negative air ion generator.

FEATURE
  • LCD display, with 1,999 counts
  • Tests air ions generator and air purifier(both positive ion & negative ion can be tested)
  • Tests the textile or cloth: Judge the ion's polarity and get the ion concentration
  • Small & light, can be hung as a necklace ion concentration Range: 10000 to 1.999×107 (ions/cc)
  • Power source: 1.5V×2 LR44 size batteries
  • Dimensions: 78 × 27 × 9mm
OPERATION
  1. Put the switch to ON position.
  2. Keep your finger touch on the square metal of the front panel and approach to the Air Ion Generator. The result is higher if the tester is close to the Ion Generator. But don³t be too close to avoid influencing the test result.
  3. Do not touch the rear square metal of the tester when testing. There is an induction panel on the back.
  4. If the reading displays "+", it means the ions are positive; if it displays "-", it means the ions are negative. If you want to know the more exact value of the air ion concentration, you may calibrate it with DLY-3 Air Ion Detector. Finding out the distance that the reading of KT-401 is equal to DLY-3. Then keep this distance to test the air ion generator.
¡¡
KT-401P NEGTIVE AIR ION TESTER
  1. Model KT-401P is a new design of mini air ion tester. It can keep the peak value (maximum reading) of negative air ion on the LCD.So, it make the reading more stable and more easy to read.
  2. Before each measuring, be sure to slip the power switch to off position. Starting to switch the KT-401P in a distance far away from ion sources ( ion generator or air purifier) to let first reading come to zero, or close to zero.
  3. Forward the KT -401P towards ion sources and move it closer to .You will find, the more close the large the reading is.So, keep a distance to get a standard reading is very important.
  4. The maximum reading in your test will stay on the LCD until you switch of the power.
  5. Try to switch off the tester when you find the Zero Reading is too large, and start a test again.

Formaldehyde Monitor is the formaldehyde gas alarm controller component system, prompted by different light environments where formaldehyde Nongduo users currently in compliance, critical, excessive (exceeding several times to display excessive), and other states, and to remind users to take the necessary measures to protect you and your family health.
  1. The icon indicates that the air quality
    Smiley face icon is clean: green light, the state indoor formaldehyde close to zero pollution, no treatment can be Plant icon is light pollution: the yellow lights, indoor formaldehyde pollution in the zero boundary condition, the proposed aquaculture ivy, spider plants, aloe and other green plants absorb formaldehyde. Ventilation window icon is heavily polluted: red lights, excessive indoor formaldehyde pollution in the state, must act immediately ventilation.
  2. materials
    Panel: the transparent parts, PC material. PC of the biggest advantages is rigid and tough, mechanical strength and nylon similar. High gloss surface. PC impact resistance than other materials.
  3. shell: ABS material. Features:
    good overall performance, high impact strength, chemical stability, good electrical properties, good flexibility.
  4. Installation: through the power cable.
Model BT402
Specifications:
Host Power Built-in lithium battery
Working temperature -20°C~40°C
Humidity
Less 90% RH
Size 80×100×38
Weight 120g ( without AC adapter)
Icon Green smiley face icon: <0.08mg/m³
Plant yellow icon: 0.08 ~ 0.12mg/m³
Red window icon:> 0.12mg/m³
Progress bar:
1 cell 0.13 ~ 0.2 mg/m³ (exceeding double)
2 cell 0.21 ~ 0.3 mg/m³ (exceeding twice)
3 cell 0.31 ~ 0.4 mg/m³ (exceeding three times)
4 grid 0.41 ~ 0.5 mg/m³ (exceeding four times)
5 grid 0.51 ~ 0.6 mg/m³ (exceeding five times)
over than 0.6 mg/m³ not be exceeded
due to a serious show.
Power consumption
<1W
AC Adapter Power input AC200V-240V(50Hz/60Hz)
Power output
DC5V 0.5A
Unit Size 27.5×62×36.5mm
Weight 20g
Testing principle
Characteristics of the instrument through which the sensor (built-in import of air quality sensor) on the induced formaldehyde in the air to determine the air pollution situation. Characteristics of conductor boot by heating, rapid, sustained uninterrupted gas sensing for pollution, the internal calculation by the well-designed program of intelligent, measured values with reference to the "international indoor environmental industry standard", when the excessive pollution, the sensor sensitivity will inducting promptly.

Air Quality Monitor Model BT403
Introduction
  1. detection index: TVOC, second-hand smoke, dust, temperature and humidity.
  2. Monitor screen color to show the air quality little exceeded (yellow): TVOC concentrations exceeding 3.0mg/M³, equivalent to room 10 M² room has half cigarettes.
    Heave (red): TVOC concentrations exceeding 25mg/M³, the equivalent of at least 3 cigarettes in the 10M² room
  3. materials
    Panel: the transparent parts, PC material. the most advantages is rigid and tough, mechanical strength the same as nylon. High gloss surface. PC impact resistance than other materials.
    Housing: ABS material. Features: good overall performance, high impact strength, chemical stability, good electrical properties, good flexibility.
  4. Installation: through the power cable.
  5. Applications: This product is suitable for the living room, bedrooms, meeting rooms, offices and other places, and the car.
How to use
  1. the dedicated AC adapter cable into the body on the back of the interface DC power outlet, USB port into the AC adapter
  2. a dedicated AC plug into a household outlet
  3. showing part should put vertically
    To make the sensor work, the back of the unit must leave at least 5cm for the wall.
    Note: a little warm when use , it is normal.
Working Environment:
  1. Working temperature: 0-40°C in the room.
  2. Please do not put in the following place:
    bathroom
    vibration area
    Where direct light
    Where dust is more
    Outside, the balcony
    near heating and cooling equipment
    Cooking oil or water will spill areas
    in the vicinity, humidity, temperature changes too much
  3. Condensation
    When in the winter, the unit form the cold room to a heating room or device in the humidity of the room.
    the unit will be attached to the internal or external water droplets (condensation). Ontology can cause condensation problems. to prevent condensation, please put the unit in a plastic bag than move to the emperature and humidity changing room , after several hours you can use the tester.
Maintenance
  1. Use dry, soft cloth to clean the body Please do not use volatile cleaning products (gasoline, thinner, alcohol, oil products) for cleaning, may cause body deformation, discoloration.
  2. Ontologies on the back of the vent the accumulation of dust, use a vacuum cleaner to suck out the dust.
    Note: Do not fall into the dust inside the fuselage.
  3. Please wipe the dust off the power plug, dust may be cause of the fire.
Detection principle
Characteristics of the instrument through which the sensor (built-in import of air quality sensor) on the air TVOC, second-hand smoke have sensors to determine the air pollution situation.
Characteristics of conductor boot by heating, rapid, sustained uninterrupted gas sensing for pollution, the internal calculation by the well-designed program of intelligent, measured values with reference to the "internationl indoor environmental industry standard", if any of the excessive pollution, the sensor sensitivity induction promptly.

Specifications:
Host Power DC5V (Please use a dedicated AC adapter)
Temperature condition 0~40°C
Humidity condition 90% rh or less (no condensation)
Dimensions 131×82×58
Weight About 300g (without AC adapter)
Indoor dust sensor
  • Mild dust: Equivalent of smoking a cigarette one time, and smoke filled the room about 15 square meters of dust content
  • Moderate dust: Equivalent of smoking three times, smoke filled the room about 15 square meters of dust content
  • Because the indoor air, placement, cigarette brands, there are some differences
Air quality sensor
  • Plants: the equivalent of smoking a cigarette, smoke filled the room about 15 square meters of dust content
  • Ventilation: the equivalent of smoking three cigarettes, smoke filled the room about 15 square meters of dust content
Temperature Sensor
  • Sun: 16 degrees Celsius
  • Snow: 28 degrees Celsius
Humidity Sensor
  • Humidification: less 30% rh
  • Sunshine: over 70% rh
AC Adapter Power input AC200V¡ª240V(50Hz/60Hz)
Power output DC5V0.5A
Unit Size 27.5×62×36.5mm
Net Weight 20g

Common Problem Solution:
Situation Please check as follows
Not shown
  • AC adapter instrument is connected with the special?
  • Dedicated AC adapter plug is plugged into socket?
Showed no change Check the air intake is blocked or not
Plant Or Ventilation icon Did not disappear instrument sites placed higher VOC concentrations continue to state,
Dust icon does not disappear instrument placed in the interior areas continued high state of dust,
Humidity No disapper
  • instrument placed in low humidity areas of the state,
  • instrument placed in places with high humidity state,
no sun or snow
  • instrument placed in low temperature state places,
  • instrument temperature of high-placed state of the place,

Model BT404
Testing principle
Characteristics of the instrument through which the sensor (built-in import of air quality sensor) on the induced formaldehyde in the air to determine the air pollution situation. Characteristics of conductor boot by heating, rapid, sustained uninterrupted gas sensing for pollution, the internal calculation by the well-designed program of intelligent, measured values with reference to the "international indoor environmental industry standard", when the excessive pollution, the sensor sensitivity will inducting promptly.
Formaldehyde Monitor
Introduction
Formaldehyde monitor system is constituted by formaldehyde gas alarm controller.
Through the different lighting display to inform the formaldehyde concentration in the current standard, critical, excessive (exceeding several times to display excessive), and other states, and to remind users to take necessary security measures to protect the health for you and your family!
  1. The icon indicates the air quality
    • Smiley face icon indicate the air is clean:
      green light, state indoor formaldehyde about zero pollution, no treatment can be done
    • Plant icon is little bit pollution:
      the yellow lights, indoor formaldehyde pollution in the zero boundary condition, the proposed aquaculture ivy, spider plants, aloe and other green plants absorb formaldehyde.
    • Ventilation window icon is heavily polluted:
      red lights, excessive indoor formaldehyde pollution in the state, must act immediately ventilation.
  2. Materials
    Panel: the transparent parts, PC material.
    PC the most advantages is rigid and tough, mechanical strength and nylon similar. High gloss surface. PC impact resistance than other materials.
  3. shell: ABS material.
    Features: good overall performance, high impact strength, chemical stability, good electrical properties, good flexibility.
  4. Installation: through the power cable.
Specifications:
Host Power Built-in lithium battery
Working temperature -20°C~40°C
Humidity
Less 90% RH
Size 80×100×38
Weight 120g ( without AC adapter)
Icon Green smiley face icon: <0.08mg/m³
Plant yellow icon: 0.08 ~ 0.12mg/m³
Red window icon:> 0.12mg/m³
Progress bar:
1 cell 0.13 ~ 0.2 mg/m³ (exceeding double)
2 cell 0.21 ~ 0.3 mg/m³ (exceeding 2)
3 cell 0.31 ~ 0.4 mg/m³ (exceeding 3 times)
4 grid 0.41 ~ 0.5 mg/m³ (exceeding 4 times)
5 grid 0.51 ~ 0.6 mg/m³ (exceeding 5 times)
over than 0.6 mg/m³ not be exceededed
due to a serious show.
Power consumption
<1W
AC Adapter Power input AC200V-240V(50Hz/60Hz)
Power output
DC5V 0.5A
Unit Size 27.5×62×36.5mm
Weight 20g

Air Quality Monitor Model BT405 We have over 70% time at home, office or sitting at the other indoor environments.
Good indoor air quality is to protect the health of the most important factor, the failure of indoor air can lead to physical discomfort, ill health (eg headache, itchy eyes, breathing difficulties, skin irritation, fatigue, or vomiting), and when you working, it will lead to high absenteeism and low productivity.
Pregnant women, children, work pressure of the white-collar workers, the elderly, people with respiratory or heart problems would be easier adverse impact of indoor air quality.
Thus we need to closely read it to know if the air is pure or not
we designed the "BT404" air quality monitor which can reflect the excellent quality of the air.
When the air quality is good, light blue, light hair; when encountering light polluted environment will show a yellow light to alert you breathe the air has been polluted;
when faced with serious pollution of the environment will show Red to alert, the air you breathe has been serious pollution, not good for human long-term stay.
  1. The color of the screen display indicate the air quality
    • Slightly exceeded (yellow): TVOC concentrations exceeding 3.0mg/m3, equivalent the 10m2 room only half cigarette.
    • Severe heavely (red): TVOC concentrations exceeding 25mg/m3, the equivalent the 10m2 room with at least 3 cigarettes.
    • Indoor temperature and humidity with a digital display, 16 oC-28 oC for the optimum temperature and the appropriate humidity is 30% -70%, Progress bar is displayed to the air pollution levels.
  2. Materials
    • Panel: the transparent parts, PC material.
      The advantage of PC material is rigid and tough, mechanical strength and nylon similar. High gloss surface. PC impact resistance than other materials.
    • Housing: ABS material.
    • ABS Features: good overall performance, high impact strength, chemical stability, good electrical properties, good flexibility.
    • Display: LED backlight, green energy. Long service life of 10 thousand hours. Response speedly, visual distance, digital high: all-digital, high-resolution graphics mode can be realized. Quality: The import of light-emitting materials, high-quality IC chip, no noise, high-power power supply. Low power consumption: less than maximum power 800W per square meter
  3. Installation: through the power cable.
  4. Applications: This product can be used for living room, bedrooms, meeting rooms, offices and the car.
the main monitoring gas:
Formaldehyde, stupid class, aromatic hydrocarbons, alcohol, smoke, temperature, humidity, TVOC hydrogen and other volatile gases, CO has some reflected.

Show Description: 3 colors LED show indoor air quality.
  • Green
    Well-lit indoor air quality, can not do any processing.
  • Yellow
    Indoor air pollution, light light, the proposed ventilation, breeding green plants absorb harmful gases.
  • Red
    Indoor air pollution a serious light, must act immediately ventilation
  • Icon is displayed every 15 seconds will flash 2 times
  • indoor temperature and humidity with a digital display
  • progress bar is displayed to the air pollution levels.
Usage:
  1. plug in and start working automatically after power equipment
  2. boot the machine after about 10 minutes after work ( when long time not use, need two hours), boot red or yellow light displayed the unit is under normal condition.
Specification
Host Power DV-5V
Size 69×100×55mm
Weight 135g(Excluding AC adapter)
Temperature Temperature measuring range:
-20oC~60 oC Accuracy:±1°C
Humidity Humidity measuring range:20~90%RH
Accuracy:5%(30~90%RH,5°C~50°C)
Power 0.5W
Common Problems Solution:
Situation Please check like this
No display 1. Power supply is plugged or not
2. Outlet has power or not
3. Plug is damaged or not
Digital number
not change
1. The unit placed in the environment
   when the indoor air quality no change
2. Check the vent is blocked or not

Air Quality Indicator Model BT406
  1. the color of light reflected by the different air quality
    • Slightly exceeded (yellow): TVOC concentrations exceeding 3.0mg/m3, equivalent in 10m2 room only half cigarettes.
    • Heavey exceeded (red): TVOC concentrations exceeding 25mg/m3, the equivalent in 10m2 room at least 3 cigarettes.
  2. Introduction of the air quality indicator material
    • Panel: The acrylic material.
    • Acrylic material characteristics:
      good transparency, more than ordinary glass, and has a crystal-like luster. Long life, light weight, only about half of ordinary glass. High surface hardness, the equivalent of aluminum. The corrosion resistance of ordinary chemicals. Good impact resistance. Completely recyclable, environmentally friendly.
    • Housing: ABS material.
      ABS material characteristics: good overall performance, high impact strength, chemical stability, good electrical properties. better than PMMA, PC and it is good flexibility.
Calibration
  1. When it is insensitive, you need to re-calibrate the instrument,
  2. Select a user that a clean environment which is a similar temperature and humidity with the environment of space.
  3. First run it for half an hour, then re-power,
  4. Power into the instrument Successive power cycle when the lamp 3 times,
    The instrument into calibration status, which is red LED light, Until the green light starts flashing the calibration is complete
  5. Then re-power the instrument to work, if the red light flashes which means the calibration failed, please re-calibration again
This product is used for the living room, bedrooms, meeting rooms, offices and other places.

The main monitoring gas:
Formaldehyde, stupid class, aromatic hydrocarbons, ethanol, second-hand smoke, hydrogen and other TVOC volatile gases, CO has some reflected.
  • When the concentration of indoor air pollutants meet relevant national standards or impact on the human body is very small, the green light shows
  • when the slightly higher than the critical value, the yellow light shows
  • when times higher than the critical value, the red light will be shown to Show reminder alerts.
Specification
Host Power AC200V-50Hz
Working temperature 0~40°C
Humidity under 90%RH (No condensation)
Size 90×60×25mm
Weight 75g
Power 0.5W

Common Problems Solution
Situation Please check as follows
No display 1. Power supply is plugged or not
2. Outlet has power or not
3. Plug is damaged or not
Digital number
not change
1. The unit placed in the environment
   when the indoor air quality no change
2. Check the vent is blocked or not



Wind Anemometer Digital Anemometer Wind Speed Wind Meter
Model BT407
Measuring Range -1045
Wind Speed Measuring Range 0.3~30m/s
Selection Yes
Accuracy of temperature ±2
Accuracy of Wind speed ±5%
Auto /ManualPower Off Yes
Low Battery Indication Yes
BackightDisplay Yes
Max/Min wind speed measuring Yes
Average And current wind speed measuring Yes
Resolution 0.1m/s 0.2
FEATURES & SPECIFICATIONS:
Measuring unit M/s,Ft/min Knots,Km/hr,Mph
CHARACTERISTICS
Power CR2032 3.0V
LCD size 30.0×25.0mm
Color Dark Gray
Net Weight 52.1g
Unit Size 105×40×15mm
Package 80PCs/Carton
Package Blister
Carton size 38.0×38.0×43.8cm
Gross Weight 9.56kg

  • Range & Accuracy:
  • Temperature: -10~50°C (+14°F~+122°F)±1°C
  • Humidity: (20%RH~99%RH)±5%
  • Features:
    Display Temp. Humidity
    simultaneously
    °C/°Funit selectable
    12-hour/24-hour time system
  • Selectable
    Integral-hour alarm function Alarm function, Calendar function
    Power Supply: 1.5V(AAA)x1,super
    Low power consumption
    Product Dimension: 106¡Á98¡Á22mm
  • Package 48PCs/carton
    Carton size: 40.8×29.5×33.5cm
    Gross Weight: 7.7kg

Model BT408

Digital Thermometer & Hygrometer
enter

Specification
Measure range: 0.00-14.00ph
Resolution: 0.01ph
Accuracy: ±0.01ph
Automatic temperature compensation: 0°C-60°C
Power supply: 2×1.5V(AG13 battery)
Operating temperature: 0°C-60°C
Calibration: manual at one point through trimmers
Dimension: 155mm×29mm×16mm
Weight: 48g
Pen-type PH meter Model BT409
  • Operation:
    remove the protective cap. first rinse the electrode with distilled water, and suck it with filter paper. turn the meter on by pressing the on key. immerse the ph meter electrode in the solution to be tested. stir gently and wait for the reading to stabilize. after use. rise the electrode with water to minimize contamination. turn the meter on by pressing the off key. always replace the protective cap after use.

  • Calibration:
    immerse the electrode in PH6.86(under the temperature of 25°C ) standard buffer solution of phosphate, and gently shake the electrode. regulate the trimmer with a screwdriver until the buffer solution value corresponding to the measurement temperature is obtained. immerse the electrode in ph 4.01 or ph 9.18 the standard buffer solution of borax. after about one minute, until the buffer solution value corresponding to the measurement temperature is obtained.

  • Important:
    the instrument¡¯s ph range must be re-calibrated whenever. approximately one month has passed from the last calibration. the electrode has been used in particularly taxing conditions. the utmost accuracy is required.

  • Battery install:
    If the meter can not be switched on or the display fades, to change batteries, pull out the battery case and replace batteries. Pay attention to the polarity of battery.

  • Warranty:
    These instruments are warranted from all defects in material and manufacturing for a period of one year from the date of purchase. If during this period, the repair or the replacement of parts is required where the damage is not due to negligence or erroneous operation by user, please return the parts to either repair will be effected free of charge.

TDSBT409
1
2
3
4
WHAT IS TDS?
Total Dissolved Solids(TDS)are the total weight of all solids (minerals, salts, or metals) that are dissolved in a given volume liter(mg/L), or in parts per million(ppm).
The lower TDS level in the water, the more efficiently your body's cells actually get hydrated by the water you drink. The higher TDS level in the water, the grater the probability of harmful contaminants that can pose health risks of hinder the on the cellular level

The EPA'S maximum contaminant levels of TDS in secondary drinking water is 500mg/L (500ppm)

FEATURES
Hold function: Saves measurements for convenient reading and recording.
Auto-off function: turn on meter after 8 minutes of non-use to conserve batteries, and will be locked automatically after 2 minutes.
Dual range: measures from 0-999ppm, with a resolution is 10 ppm, indicated by drinking×10 image, factory calibrated.
Range: 0-9990ppm
Accuracy: ±2%
Battery: 2×1. 5V(button cell)
Size: 140×23×15MM
  • Use the TDS METER to:
    1. Check the performance of your water filter
    2. Check for hardness (1grain=17ppm)
    3. Make sure you always drink pure water!


  • Instructions for the TDS meter:
    1. Remove the protective cap.
    2. Turn the tds meter on. the on/off switch is located on the panel.
    3. Immerse meter into the water/solution up to the maximum immersion level(2'')
    4. Wait until the display stabilizes. the tds meter automatically compensates for temperature variations. Once the readout is stabilized(10-30 seconds),press the hold button to view the reading out of the water.
    5. To use the thermometer, turn the meter on and press the temp button. Pressing the temp button again will switch it to tds mode.
    6. After usage, shake off water from your meter or wipe it with a tissue.
    7. Do not touch the metal probes. Clean the probes with rubbing alcohol and a cotton swab.

  • CALIBRATION:
    Your meter has been calibrated in our factory with international standard calibration solution, which is suitable for most applications. Recalibration may be necessary from time-to-time depending on usage.

  • Three Year Limited Warranty:
    This product is warranted to the purchaser against material and workmanship for three (3) years from the date of purchase.
    What is covered: Repair of parts and labor, or replacement at the company's option. Transportation charges to the purchaser.
    What is not covered: Transportation charges to the company. Damages from abuse or improper maintenance (see operating instructions and precautions).
    Any other consequential damages, or incidental expenses, including damages to property. Some states do not allow the exclusive or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

  • Implied warranties:
    Any implied warranties, Including implied warranties of merchantability and fitness for a particular purchase, are limited in duration to three years from the date of purchase. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
    To the extent any provision of this warranty is prohibited by federal or state law and cannot be preempted, it shall not be applicable. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.

  • Precautions:
    Do not drop the entire tds meter in the water or dip beyond the maximum immersion level. This unit is not water-tight and is not covered under the warranty is not water enters the unit.
    Do not store the tds meter under high temperature or direct sunlight. This will shorten the life-span of the product and potentially void the warranty.
    The TDS-1 is calibrated at 50ppm. It is recommended that the calibration level be as close as possible to sample to be tested. If you are testing higher p (member, water quality association).
About Contact